Wiring Distribution Facts

As a network administrator, you are often responsible for both data and telephone wiring for your organization. The following table describes the components used for wiring distribution.

Component Description
Demarcation point (demarc) When you contract with a local exchange carrier (LEC) for data or telephone services, they install a physical cable and a termination jack onto your premises. The demarcation point (demarc) is the line that marks the boundary between the telco equipment and the private network or telephone system.
  • Typically, the LEC is responsible for all equipment on one side of the demarc, and the customer is responsible for all equipment on the other side of the demarc.
  • The demarc is also called the minimum point of entry (MPOE) or the end user point of termination (EU-POT).
  • The demarc is typically located in the bottom floor of a building, just inside the building. For residential service, the demarc is often a small box on the outside of the house.
  • For business installations, the demarc is often identified by an orange plastic cover on the wiring component.
Main Distribution Frame (MDF) The main distribution frame (MDF) is the main wiring point for a building. The MDF is typically located on the bottom floor or basement. The LEC typically installs the demarc to the MDF.
Intermediate Distribution Frame (IDF) An intermediate distribution frame (IDF) is a smaller wiring distribution point within a building. IDFs are typically located on each floor directly above the MDF, although additional IDFs can be added on each floor as necessary.
Demarc extension As it name implies, a demarc extension extends the demarcation point from its original location to another location within the building.
  • The demarc extension typically consists of a single wire bundle that attaches to the existing demarc and supplies a termination point to a different location.
  • You might need a demarc extension if your network occupies an upper floor of a building. The LEC will typically install the demarc into the MDF on the bottom floor, and you will need to install an extension to place the demarc into the IDF on your floor.
  • You are typically responsible for installing the demarc extension, or the LEC might do it for an additional charge.
Vertical cross connect A vertical cross connect connects the MDF on the main floor to IDFs on upper floors. Cabling runs vertically (up and down) between the MDF and the IDFs.
Horizontal cross connect A horizontal cross connect connects IDFs on the same floor. Cabling runs horizontally (sideways) between the IDFs.
25 pair 25 pair cables consist of 25 pairs of copper wires in a single bundle (containing a total of 50 wires). 25 pair cables are often used for telephone installations that have multiple telephone lines, to replace multiple Cat3/5/5e/6 cables in a single bundle, and for horizontal and vertical cross connects between the MDF and IDFs. Individual wires within the 25 pair cable use the following color coding scheme:
  • A total of 10 colors are used in two different groups:
    • Group 1 colors are white, red, black, yellow, and violet.
    • Group 2 colors are blue, orange, green, brown, and slate.
  • There are 5 wires of each color.
  • Every colored wire in group 1 is paired with each color in group 2. For example, you will have the following pairs for the white wires:
    • White with blue
    • White with orange
    • White with green
    • White with brown
    • White with slate
  • Instead of using solid colors, some schemes use striped wires to uniquely identify each wire and its matching wire. For example, the white wire with a blue stripe is twisted with the blue wire with a white stripe, and the red wire with the orange stripe is twisted with the orange wire with the red stripe.
An RJ-21 connector is used to connect 25 pair cable to other wiring devices, or you can manually connect each wire to the necessary location.
100 pair 100 pair cable consists of 100 pairs of copper wires in a single bundle (containing 200 wires).
  • 100 pair wires use the same coloring scheme as 25 pair wires, repeated 4 times.
  • Each bundle of 25 wires is often wrapped together with a colored nylon string to help separate wires of the same color.
66 block A 66 block is a punchdown block used for connecting individual copper wires together.
  • The 66 block has 25 rows of four metal pins. Pushing a wire into the pin pierces the plastic sheath on the wire, making contact with the metal pin.
  • There are two different 66 block configurations:
    • With the 25 pair block (also called a non-split block), all 4 pins are bonded (electrically connected). Use the 25 pair block to connect a single wire with up to 3 other wires.
    • With the 50 pair block (also called a split block), each set of 2 pins in a row are bonded. The left pin is connected with the middle left pin, while the right pin is connected with the middle right pin. Use the 50 pair block to connect a single wire to one other wire.
  • With a 50 pair block, use a bridge clip to connect the left two pins with the right two pins. Adding or removing the bridge clip is an easy way to connect wires within the row for easy testing purposes.
66 blocks are used primarily for telephone applications. When used for data applications:
  • Be sure to purchase 66 blocks rated for Cat5.
  • When inserting wires in the block, place both wires in a pair through the same slot to preserve the twist as much as possible.
110 block A 110 block is a punchdown block used for connecting individual wires together.
  • The 110 block comes in various sizes for connecting pairs of wires (for example 50, 100, or 300 pair).
  • The 110 block has rows of plastic slots. Each plastic slot connects two wires together:
    • Place the first wire in the plastic slot on the 110 block.
    • Insert a connecting block over the wire and slot. The connecting block has metal connectors that pierce the plastic cable sheath.
    • Place the second wire into the slot on the connecting block.
  • C-4 connectors connect four pairs of wires; C-5 connectors connect five pairs of wires.
  • When connecting data wires on a 110 block, you typically connect wires in the following order:
    • White wire with a blue stripe, followed by the solid blue wire.
    • White wire with an orange stripe, followed by the solid orange wire.
    • White wire with a green stripe, followed by the solid green wire.
    • White wire with a brown stripe, followed by the solid brown wire.
    Tip: Use BLOG (BLue-Orange-Green) to remember the wire order, and remember to start with the white striped wire first.
110 blocks can be used for both telephone and data, and are better suited for Cat5 installations. When using for Cat5 wiring, be sure to preserve the twists in each wire pair to within one-half of an inch of the connecting block.
Patch panel A patch panel is a device that typically connects individual stranded wires into female RJ-45 connectors. For example, you might connect 4 pairs of wires from a punchdown block to a port on the patch panel. On the patch panel, you then connect drop cables (cables with RJ-45 connectors) to the patch panel on one end and a computer on the other end.

Use a punch down tool to insert wires into 66 or 110 blocks.